DAIKIN Altherma heat pump 12 kW EPRA12EV3 1PH/1F outdoor unit
Wall-mounted air-to-water heat pump with heating function only: built-in all hydraulic components means that no third-party components are needed electrical box and hydraulic components are located at the front, making access and installation easier small dimensions guarantee a small space installation elegant appearance guaranteed operating range up to -28°C °C
THE HEAT PUMP OUTDOOR UNIT IS A SET WITH THE INDOOR UNIT AND BOTH ITEMS SHOULD BE ADDED TO THE CART.
EPRA12EV3 is compatible with indoor units: ETBH12E9W ETBH12E6V
Product features %p10 /%
-
The outdoor unit extracts heat from the outside air, even at a temperature of -28°C
-
Tank stainless steel hot water with pojemności180 or 230 liters connected to a heat pump for ease of installation
-
The inclusion of all plumbing components means they are not needed no third party parts
-
The outdoor unit supplies outlet water at a temperature of 65°C at an ambient temperature of -15°C
%p34/ % -
The outdoor unit limits the loss of heating capacity down to the ambient temperature -15°C
-
Energy-saving system only for heating based on air-to-water heat pump technology
-
Choosing a product using refrigerant R-32 reduces environmental impact by 68% compared to products using refrigerant R-410A and, thanks to its high energy efficiency, leads directly to a reduction in energy consumption and requires a 30% less refrigerant charge
-
WLAN card
is included -
Quick setup in 9 steps with the high-resolution color interface wizard
The elegant design of the unit matches other household appliances.
Heating capacity Min. kW 3.44 (1) Nom. kW 6.17 (2) Max. kW 9.97 (1)
Power consumption Heating Min. kW 0.70 (5) Nom. kW 1.21 (2) Max. kW 2.21 (5)
Hot water from 10°C to 50°C Nom. kWh 3.09 (6)
Heat up time from 10°C to 50°C hr 2 hr. 10 min.COP 5.10 (2)
Domestic hot water and heating
Declared load profile L Moderate climate Water heating energy efficiency class A+ Space heating Water outlet temp. for temperate cli. conditions 55°C
General information
SCOP 3.53 Seasonal space heating eff. class A++ Water outlet temp. for temperate cli. conditions 35°C General information SCOP 4.84 Seasonal efficiency class heating A+++
Notes
(1) - Efficiency according to standard EN14511, valid for heated water range dT = 3~8°C at temperature Ta 7°C
(2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
(3) - Cooling: EW 12 ℃ ; LW 7 ℃ ; ambient conditions: 35°CDB
(4) - Cooling: EW 23 ℃ ; LW 18 ℃ ; ambient conditions: 35°CDB
(5) - Power consumption is the sum of the power consumption of the indoor and outdoor units together with the circulation pump; in accordance with EN14511
(6) - Test in Ta DB/WB conditions 7°C/6°C.Conducted according to EN 16147.