Enphase IQ8MC-72-INT Microinverter Microinverter Technical Parameters INPUT DATA (DC)

Typical Module Compliance 54-ogniwa/108 half-cells, 60-ogniwa/120 half-cells, 66-ogniwa/132 półogniw, 72-ogniwa/144 half-cells No forced DC/AC ratio and maximum input power.Modules can be paired provided that the maximum input voltage is not exceeded and the maximum input current of the inverter at the lowest and highest temperature is respected.

Minimum/Maximum Input Voltage [V] 18/60

Starting Input Voltage [V] 22

Rated Input Voltage [V] 35,0

Minimum/Maximum MPP Voltage [V] 25/45

Minimum/Maximum Operating Voltage [V]   18/49

Maximum input current [A]   14

Maximum input DC short circuit current [A]   25 Maksymalny short circuit current for modules (Isc) allowed to pair with IQ8 Series Microinverters: 20 A (calculated with safety factor 1,25 according to IEC standard 62548).

Maximum input power [W] 480

OUTPUT DATA (AC)

Maximum apparent power [VA] 330

Rated power [W] 325

Rated mains voltage [V] 230

Minimum/maximum mains voltage [V] 184/276

Maximum output current [A]   1,43

Rated frequency [Hz] 50

Minimum/maximum frequency [Hz] 45/55

Mechanical data

Dimensions (H x W x D) 212 mm x 175 mm x 30,2 mm (without mounting brackets)

AC connector type IQ Cabling (see separate data sheet for cables and accessories)

DC connector type Stäubli MC4

Safety standards Enphase

Grid compatibility (with IQ Relay) EN 50549-1

Safety EN IEC 62109-1, EN IEC 62109-2

EMC EN IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-3, EN IEC 50065-1, 50065-2-1, EN55011

Product labels CE

Advanced network features Export limiting, phase imbalance management, phase loss detection, power factor control Q (U), cos (phi) (P)

Microinverter communication Power line communication (PLC) 110–120 kHz (class B), narrow band 200 Hz