SUNTREE DC överspänningsskydd, överspänningsskydd 3P T2 1000V DC 20-40KA

SUNTREE DC överspänningsskydd, överspänningsskydd 3P T2 1000V DC 20-40KA

Tillverkare
Suntree
Tillverkarens kod
SUP2H-PV T2
Nominell urladdningsström
7KA
Antal polacker
3P
Urladdningsström
500VDC/800V/1000VDC
Max-urladdningsström
20KA/40KA/60KA
Visa mer
Pris
216,47 kr +MOMS
18,90 €
1 ×
18,90 € +MOMS
(1 pc.)
grundpris
216,47 kr
1 pc.
15+ st.
200,32 kr
1 pc.
30+ st.
185,77 kr
1 pc.
Denna säljare svarar snabbt
Erbjudande från leverantören:
Logga in för att se leverantörsinformation
Verifierad
Avsändningsland:
Ungern
Destinationsländer:
+26 mer
Tillgänglighet:
Avsändningstid:
2 dagar
Betalningsmetoder som rekommenderas av merXu:
Rekommenderad av merXu
merXu Protected Payments
merXu Protected Payments
Säkra din betalning fram till leverans. Kostnadsfritt.
Läs mer
Alternativa betalningsmetoder:
ADYEN_BILLIE
Kredit / Betalkort
ADYEN_IDEAL
Sofort
EPS
Trustly
Banköverföring
Parametrar
Tillverkare
Suntree
Tillverkarens kod
SUP2H-PV T2
Nominell urladdningsström
7KA
Antal polacker
3P
Urladdningsström
500VDC/800V/1000VDC
Max-urladdningsström
20KA/40KA/60KA
Driftstemperatur
-40℃~+85℃
Teststandarder
GB/T118802.1,IEC61643-31
Skyddsnivå(In) Upp
≤2.8KV/4.5KV
Vågtyp
Typ II (T2)
Produkttyp
DC SPD
Skyddsnivå B,C,D Klass
D,C,B
Beskrivning

The Cooper Suntree three-module photovoltaic Surge Protective Device (SPD) (with three-step DC switching device) features visual indication and optional remote contact signaling (floating changeover contact) for use in PV systems. These complete surge protective devices are suitable for all PV systems in accordance with IEC 60364-7-712. Includes a five year limited warranty.

These pre-wired solutions consist of a base and locking modules that feature a combined disconnection and short-circuiting (shunting) device with safe electrical isolation to prevent fire damage due to DC arcs. An integrated DC fuse allows safe module replacement without arc formation. In case of insulation faults in the generator circuit, a reliable and tested fault-resistant `l circuit prevents damage to the surge protective devices.

The green and red visual indicator flags show the module protective status (green = good, red = replace). Apart from this visual indication,the remote signaling option features a three terminal floating changeover contact that can be used as a make or break contact depending on the particular monitoring system design employed.

Ny på att handla hos merXu?

Det är enklare än du tror. Vi tillhandahåller en steg-för-steg guide

Förhandla med säljaren.

Du kan kontakta säljaren för att justera din beställning, förhandla om priset eller fråga om andra erbjudanden från deras portfölj innan du gör ett köp. Välj och klicka på erbjudandet du är intresserad av. Hitta knappen "SKICKA FÖRFRÅGAN" på högra sidan av erbjudandet och du kommer direkt att flyttas till en chatt med säljaren