merXu
Prekliči
merXu Protected Payments
Zagotovite svoje plačilo do dostave.
SUNTREE DC prenapetostna zaščita, prenapetostni odvodnik 3P T2 1000V DC 20-40KA

SUNTREE DC prenapetostna zaščita, prenapetostni odvodnik 3P T2 1000V DC 20-40KA

Proizvajalec
Suntree
Koda proizvajalca
SUP2H-PV T2
Nazivni izpustni tok
7KA
Število polj
3P
Razelektritveni tok
500VDC/800V/1000VDC
Največji tok praznjenja
20KA/40KA/60KA
Pokaži več
Cena
18,90 € +DDV
1 ×
18,90 € +DDV
(1 pc.)
osnovna cena
18,90 €
1 pc.
15+ kosov
17,49 €
1 pc.
30+ kosov
16,22 €
1 pc.
Ta prodajalec se hitro odzove
Ponudba dobavitelja:
Prijavite se za ogled podrobnosti dobavitelja
Preverjeno
Država odpreme:
Madžarska
Namembne države:
+26 več
Čas odpreme:
2 dni
Načini plačila, ki jih priporoča merXu:
Priporoča merXu
merXu Protected Payments
merXu Protected Payments
Zagotovite svoje plačilo do dostave. Brezplačno.
Preberite več
Alternativni načini plačila:
ADYEN_BILLIE
Kreditna/debetna kartica
ADYEN_IDEAL
Sofort
EPS
Trustly
Elektronsko nakazilo
Parametri
Proizvajalec
Suntree
Koda proizvajalca
SUP2H-PV T2
Nazivni izpustni tok
7KA
Število polj
3P
Razelektritveni tok
500VDC/800V/1000VDC
Največji tok praznjenja
20KA/40KA/60KA
Delovna temperatura
-40℃~+85℃
Testni standardi
GB/T118802.1,IEC61643-31
Raven zaščite (in)Up
≤2.8KV/4.5KV
Vrsta valov
Tip II (T2)
Tip izdelka
DC SPD
Stopnja zaščite B,C,D Grade
D,C,B
Opis

The Cooper Suntree three-module photovoltaic Surge Protective Device (SPD) (with three-step DC switching device) features visual indication and optional remote contact signaling (floating changeover contact) for use in PV systems. These complete surge protective devices are suitable for all PV systems in accordance with IEC 60364-7-712. Includes a five year limited warranty.

These pre-wired solutions consist of a base and locking modules that feature a combined disconnection and short-circuiting (shunting) device with safe electrical isolation to prevent fire damage due to DC arcs. An integrated DC fuse allows safe module replacement without arc formation. In case of insulation faults in the generator circuit, a reliable and tested fault-resistant `l circuit prevents damage to the surge protective devices.

The green and red visual indicator flags show the module protective status (green = good, red = replace). Apart from this visual indication,the remote signaling option features a three terminal floating changeover contact that can be used as a make or break contact depending on the particular monitoring system design employed.

Novi pri nakupovanju na merXu?

Je lažje, kot mislite. Ponujamo vam vodnik korak za korakom

Pogajajte se s prodajalcem.

Lahko se obrnete na prodajalca, da prilagodite svoje naročilo, pogajate o ceni ali povprašate o drugih ponudbah iz njegovega portfelja pred nakupom. Izberite in kliknite na ponudbo, ki vas zanima. Najdite gumb "POŠLJI POVPRAŠEVANJE" na desni strani ponudbe in preusmerjeni boste neposredno na klepet s prodajalcem

Ena zahteva, več ponudb
Ustvarite poizvedbo tako, da dobavitelju poveste, kaj potrebujete.