merXu Protected Payments
Asigurați-vă plata până la livrare.
Protector de supratensiune SUNTREE DC, descărcător de supratensiune 3P T1+T2 1000V DC 20-40KA

Protector de supratensiune SUNTREE DC, descărcător de supratensiune 3P T1+T2 1000V DC 20-40KA

Producător
Suntree
Codul producătorului
SUP2-DC T1+T2
Curent nominal de descărcare
7KA
Numărul de poli
3P
Curent de descărcare
500VDC/800V/1000VDC
Curent maxim de descărcare
20KA/40KA/60KA
Afișează mai multe
Preț
148,78 RON +TVA
29,90 EUR
1 ×
29,90 EUR +TVA
(1 buc.)
preț de bază
148,78 RON
1 buc.
15+ buc.
138,83 RON
1 buc.
30+ buc.
133,85 RON
1 buc.
Răspunde rapid
Oferta furnizorului:
Autentifică-te pentru a vedea detaliile furnizorului
Verificat
Țara de expediere:
Ungaria
Țări de destinație:
+26 Mai mult
Disponibilitate:
Timp de expediere:
2 zile
Metode de plată recomandate de merXu:
Recomandat de merXu
merXu Protected Payments
merXu Protected Payments
Asigurați-vă plata până la livrare. Gratuit.
Află mai multe
Metode alternative de plată:
ADYEN_BILLIE
Card de credit / debit
ADYEN_IDEAL
Sofort
EPS
Trustly
Transfer bancar
Parametri
Producător
Suntree
Codul producătorului
SUP2-DC T1+T2
Curent nominal de descărcare
7KA
Numărul de poli
3P
Curent de descărcare
500VDC/800V/1000VDC
Curent maxim de descărcare
20KA/40KA/60KA
Temperatura de Operare
-40℃~+85℃
Standarde de testare
GB/T118802.1,IEC61643-31
Nivel de protecție(In)Up
≤2.8KV/4.5KV
Tipul de undă
Tip II (T2)
Tip produs
DC SPD
Nivel de protecție B,C,D
D,C,B
Descriere

The Cooper Suntree three-module photovoltaic Surge Protective Device (SPD) (with three-step DC switching device) features visual indication and optional remote contact signaling (floating changeover contact) for use in PV systems. These complete surge protective devices are suitable for all PV systems in accordance with IEC 60364-7-712. Includes a five year limited warranty.

These pre-wired solutions consist of a base and locking modules that feature a combined disconnection and short-circuiting (shunting) device with safe electrical isolation to prevent fire damage due to DC arcs. An integrated DC fuse allows safe module replacement without arc formation. In case of insulation faults in the generator circuit, a reliable and tested fault-resistant `l circuit prevents damage to the surge protective devices.

The green and red visual indicator flags show the module protective status (green = good, red = replace). Apart from this visual indication,the remote signaling option features a three terminal floating changeover contact that can be used as a make or break contact depending on the particular monitoring system design employed.

Nou în cumpărăturile de la merXu?

Este mai ușor decât crezi. Îți oferim un ghid pas cu pas

Negociați cu vânzătorul.

Puteți contacta vânzătorul pentru a ajusta comanda, negocia prețul sau pentru a întreba despre alte oferte din portofoliul lor înainte de a face o achiziție. Alegeți și faceți clic pe oferta care vă interesează. Găsiți butonul "TRIMITE ÎNTREBARE" pe partea dreaptă a ofertei și veți fi redirecționat direct la o conversație cu vânzătorul

O singură cerere, mai multe oferte
Cere oferte de preț spunându-le furnizorilor de ce ai nevoie