merXu

Annuleren
Bruk-Bet Extreme Plus fotovoltaïsche module BEM.WS-360

Bruk-Bet Extreme Plus fotovoltaïsche module BEM.WS-360

Bruk-bet
Fabrikant
Bruk-Bet
Aanvraag indienen
Dit aanbod is niet meer actief. Voeg een aanvraag toe en ontvang aanbiedingen van meerdere verkopers.
Andere verkopers bieden dit product aan
undefined undefined
undefined undefined
Parameters
Fabrikant
Bruk-Bet
Beschrijving

Electrical Parameters STC

  • Rated power [W]: 360

  • % p10/%

    Short-circuit current [A]: 9,87

  • Maximum current [A]: 9,41

    %p19/ %
  • Open-circuit voltage [V]: 45,29

  • Maximum voltage [V]: 38,27

    % p29/%
  • Efficiency [%]: 19,63

STC values ​​measured under standard test conditions (STC): solar irradiance 1000 W/m², Air mass factor 1,5 AM and cell temperature 25 °C.STC measurement tolerance ± 2 %

Electrical parameters NMOT

  • Rated power [W]: 270,8

  • Short-circuit current [A]: 7,96

  • Maximum current [A ]: 7,56

  • Open-circuit voltage [V]: 42,73

  • Maximum voltage [V]: 35,83

NMOT values ​​are measured under test conditions 800 W/m², ambient temperature 20 °C, wind speed 1 m/s, Air mass coefficient AM 1,5.STC measurement tolerance ± 2%; NMOT ± 5%

Electrical parameters LIC

  • Power rated [Wp]: 69,7

W LIC measured under Test Conditions: Solar irradiance 200 W/m², Air mass coefficient 1.5 AM and cell temperature 25 °C.STC measurement tolerance ± 5 %.

Application Parameters

  • Power Tolerance: 0/+4,99 Wp

  • Safety class: II

  • Maximum system voltage: 1000/1500 VDC

  • % p21/% Operating temperature: -40 / +85 °C

  • Current reverse protection: 22 A

Temperature Parameters

  • NMOT (800 W/m², 1.5 AM, % p41/% °C, 1 m/s): 42.7 °C

  • Temperature intensity coefficient: 0,045 %/°C % p49/%

  • Temperature voltage factor: -0,276 %/°C

  • Temperature power factor: %p58/ % %/°C

Strength parameters

  • Photovoltaic modules for terrestrial applications: IEC 61215 : 2016

  • Photovoltaic module safety rating: IEC 61730 : 2016

    %p78 /%
  • Maximum load IEC 61215 : 2016: 8100 Pa (825 kg/m²)

  • %p88/ % Maximum wind suction IEC 61215 : 2016: 5400 Pa (550 kg/m²)

  • IEC hail ball 61215 : 2016: ϕ = 55 mm, V=33,9 m/s

  • IEC fire resistance 61730 : %p107 /% Class C

Mechanical parameters

  • Length [mm] : 1825

  • Width [mm]: 1005

  • Thickness [mm] : 40

  • Weight [kg]: 20,5

Construction

  • Front glass: 3,2 mm, Tempered

  • Encapsulant: Foil EVA

  • Frame: Anodized aluminum, Silver

  • Cell type: Monocrystalline

    %p158/ %
  • Number of cells: 66 (6x11)

  • Connection socket: IP67, 3 diodes by- pass

  • Wiring: 2 x 1100 mm, ϕ = 4 mm²

  • %p179 /%

    Connectors: MC4 compatible, IP68

Packing

%p190/ %
  • Packing method: Carton 2,0 x 1,2 x 1,2 m

  • Quantity: 26 Pieces/Pallet

  • Transport: 26 Pallets/TIR

  • Eén aanvraag, meerdere offertes
    Maak onderzoek door leverancier te vertellen wat je nodig hebt.