Quadro elettrico 1000V CA/CC 2 perizoma T1+T2 różn.MC4

Quadro elettrico 1000V CA/CC 2 perizoma T1+T2 różn.MC4

258,14 € +IVA
1.117,12 PLN
1 pc.
Prezzo
258,14 € +IVA
1.117,12 PLN
1 ×
1.117,12 PLN +IVA
(1 pc.)
Offerta del fornitore:
Accedi per vedere i dettagli del fornitore
Verificato
Paese di spedizione:
Polonia
Paesi di destinazione:
+26 di più
Metodi di pagamento consigliati da merXu:
Raccomandato da merXu
merXu Protected Payments
merXu Protected Payments
Assicurare il pagamento fino alla consegna. Gratuito.
Per saperne di più
Metodi di pagamento alternativi:
Blik
Carta di credito / debito
Banca online
Bonifico bancario
Descrizione
PV DC/AC C switchgear 1000V Photovoltaics 2 thong T1+T2 + residual current device

A photovoltaic installation, regardless of its size, location and generator power, must include specialized RPV photovoltaic switchboards in its structure, which serve as:

• protection against reverse currents occurring in parallel strings,

• DC side overvoltage protection,T1+T2

• AC, C side overvoltage protection

• main switch of the photovoltaic generator,

• gross measurement of energy transferred from the PV generator to the DSO network

Technical data:

Electrical parameters

• max. DC voltage:1000V

• max. input current per string:15A

• max. number of strings:2

• max. output breaker current:32A

• Number of outputs (MPPT inverter):2

Lightning protection

DC : AC :

• Security class: II

• Nominal discharge current:20kA 20kA

• max. discharge current:40kA 40kA

• Voltage protection level:4.0kV 1.2kV

• max. continuous working voltage:1060V 275VAC

System

• IP protection class:IP65

• Output switch: Isolating switch

• Waterproof connectors SMC4: Standard

• PV DC fuse: Standard

• Surge Protection: Standard

Mechanical parameters

• Type of mounting: Wall-mounted

RESIDUAL CURRENT SWITCH 40A 4P 100mA AC TYPE

Series -SR6HM

Sensitivity - AC

Voltage -400V

Frequency -50/60 Hz

Rated current -40A

Number of Poles -4P

Rated residual current -100mA

Rated current switching capacity -500A

Rated insulation -500V

Voltage surge resistance -6000V

Trigger time -0,1s

Short-circuit making capacity -6 kA

Degree of protection - IP 20

Electrical life -4000

Service life - mechanical -4000

Connection terminal tightening torque -3Nm

Rail connection - comb

Mounting - DIN rail

Hermetic switchboards of the RH series "NEO" they are intended for domestic and industrial use with the possibility of installing overcurrent switches and electrical devices.They come in a surface-mounted version and are widely used in installations outside buildings.

ADDITIONAL CONNECTORS INCLUDED MC4 -4SZT.

OTHER ARTICLES FOR PHOTOVOLTAICS ARE ALSO AVAILABLE

Nuovo nell'acquisto su merXu?

È più facile di quanto pensi. Ti forniamo una guida passo-passo

Negoziare con il venditore.

Puoi contattare il venditore per modificare il tuo ordine, negoziare il prezzo o informarti su altre offerte del loro portafoglio prima di effettuare un acquisto. Scegli e clicca sull'offerta che ti interessa. Trova il pulsante "INVIA RICHIESTA" sul lato destro dell'offerta e sarai indirizzato direttamente a una chat con il venditore

Una richiesta, più preventivi
Creare un'inchiesta dicendo al fornitore ciò di cui si ha bisogno.