merXu
Otkazati
merXu Protected Payments
Osigurajte svoje plaćanje do isporuke.
SUNTREE DC zaštita od prenapona, odvodnik prenapona 3P T1+T2 1000V DC 20-40KA

SUNTREE DC zaštita od prenapona, odvodnik prenapona 3P T1+T2 1000V DC 20-40KA

Proizvođač
Suntree
Šifra proizvođača
SUP2-DC T1+T2
Nazivna struja pražnjenja
7KA
Broj Poljaka
3P
Struja pražnjenja
500VDC/800V/1000VDC
Maksimalna struja pražnjenja
20KA/40KA/60KA
Prikaži više
Cijena
29,90 € +PDV
1 ×
29,90 € +PDV
(1 PC.)
osnovna cijena
29,90 €
1 PC.
15+ kom.
27,90 €
1 PC.
30+ kom.
26,90 €
1 PC.
Ovaj prodavač brzo odgovara
Ponuda dobavljača:
Prijavite se kako biste vidjeli detalje dobavljača
Provjereno
Zemlja otpreme:
Mađarska
Zemlje odredišta:
+26 više
Vrijeme otpreme:
2 dana
Metode plaćanja koje preporučuje merXu:
Rreporučeno od merXu
merXu Protected Payments
merXu Protected Payments
Osigurajte svoje plaćanje do isporuke. Besplatno.
Saznajte više
Alternativni načini plaćanja:
ADYEN_BILLIE
Kreditna/debitna kartica
ADYEN_IDEAL
Sofort
EPS
Trustly
Žični prijenos
Parametri
Proizvođač
Suntree
Šifra proizvođača
SUP2-DC T1+T2
Nazivna struja pražnjenja
7KA
Broj Poljaka
3P
Struja pražnjenja
500VDC/800V/1000VDC
Maksimalna struja pražnjenja
20KA/40KA/60KA
Radna temperatura
-40℃~+85℃
Standardi ispitivanja
GB/T118802.1,IEC61643-31
Povećanje razine zaštite
≤2.8KV/4.5KV
Vrsta vala
Tip II (T2)
Vrsta proizvoda
DC SPD
Razina zaštite B,C,D Grade
D,C,B
Opis

The Cooper Suntree three-module photovoltaic Surge Protective Device (SPD) (with three-step DC switching device) features visual indication and optional remote contact signaling (floating changeover contact) for use in PV systems. These complete surge protective devices are suitable for all PV systems in accordance with IEC 60364-7-712. Includes a five year limited warranty.

These pre-wired solutions consist of a base and locking modules that feature a combined disconnection and short-circuiting (shunting) device with safe electrical isolation to prevent fire damage due to DC arcs. An integrated DC fuse allows safe module replacement without arc formation. In case of insulation faults in the generator circuit, a reliable and tested fault-resistant `l circuit prevents damage to the surge protective devices.

The green and red visual indicator flags show the module protective status (green = good, red = replace). Apart from this visual indication,the remote signaling option features a three terminal floating changeover contact that can be used as a make or break contact depending on the particular monitoring system design employed.

Novi ste u kupovini na merXu?

Jednostavnije je nego mislite. Pružamo vam korak-po-korak vodič

Pregovarajte s prodavateljem.

Možete kontaktirati prodavatelja kako biste prilagodili svoju narudžbu, pregovarali o cijeni ili se raspitali o drugim ponudama iz njihovog portfelja prije nego što obavite kupnju. Odaberite i kliknite na ponudu koja vas zanima. Pronađite gumb "POŠALJI UPIT" s desne strane ponude i bit ćete preusmjereni izravno na chat s prodavateljem

Jedan zahtjev, više ponuda
Napravite upit tako što ćete dobavljaču reći što trebate.