Appareillage 1000V AC DC 1 chaîne T1+T2 e.+déclencheur
Control box + safety button
Regardless of its size, location and generator power, a photovoltaic installation must include specialized RPV photovoltaic switchboards in its structure, which serve as:
• protection against reverse currents occurring in parallel strings,
• DC side surge protection,
• AC side surge protection,
• main switch of the photovoltaic installation generator,
• gross measurement of energy transferred from the PV generator to the OSD grid
Technical data:
Electrical parameters
• Max. DC voltage: 1000V
• Max. input current per string: 15A
• Max. number of strings: 1
• Max. output switch current: 32A
• Number of outputs (inverter MPPT): 1
Lightning protection
DC: AC:
• Protection class: II T1 +T2 C
• Nominal discharge current: 20kA 20kA
• Max. discharge current: 40kA 40kA
• Voltage protection level: 4.0kV 1.2kV
• Max. continuous operating voltage: 1060V 275VAC
System
• IP protection class: IP65
• Output switch: Isolation switch
• Waterproof connectors SMC4: Standard
• PV DC fuse: Standard
• Surge protection: Standard
Mechanical parameters
• Mounting type: Wall-mounted
Distribution boards Hermetic RH "NEO" series are designed for home and industrial use with the possibility of installing overcurrent circuit breakers and electrical devices.They come in a surface-mounted version and are widely used in installations outside buildings.
ADDITIONAL CONNECTORS INCLUDED MC4 - 4SZT.
ALSO OFFERS OTHER PRODUCTS FOR PHOTOVOLTAICS