merXu
Cancelar
merXu Protected Payments
Asegure su pago hasta la entrega.
Protector contra sobretensiones de CC SUNTREE, descargador de sobretensiones 3P T1+T2 1000V CC 20-40KA

Protector contra sobretensiones de CC SUNTREE, descargador de sobretensiones 3P T1+T2 1000V CC 20-40KA

Fabricante
Suntree
Código fabricante
SUP2-DC T1+T2
Corriente de descarga nominal
7KA
Número de polos
3P
Corriente de descarga
500VDC/800V/1000VDC
Corriente de descarga máxima
20KA/40KA/60KA
Mostrar más
Precio
29,90 € +IVA
1 ×
29,90 € +IVA
(1 pc.)
precio básico
29,90 €
1 pc.
15+ uds.
27,90 €
1 pc.
30+ uds.
26,90 €
1 pc.
Este vendedor responde rápidamente
Oferta del proveedor:
Inicie sesión para ver los detalles del proveedor
Verificado
País de envío:
Hungría
Países de destino:
+26 más
Disponibilidad:
Tiempo de envío:
2 días
Formas de pago recomendadas por merXu:
Recomendado por merXu
merXu Protected Payments
merXu Protected Payments
Asegure su pago hasta la entrega. Gratuito.
Más información
Métodos de pago alternativos:
ADYEN_BILLIE
Tarjeta de crédito/débito
ADYEN_IDEAL
Sofort
EPS
Trustly
Transferencia bancaria
Parámetros
Fabricante
Suntree
Código fabricante
SUP2-DC T1+T2
Corriente de descarga nominal
7KA
Número de polos
3P
Corriente de descarga
500VDC/800V/1000VDC
Corriente de descarga máxima
20KA/40KA/60KA
Temperatura de funcionamiento
-40℃~+85℃
Estándares de prueba
GB/T118802.1,IEC61643-31
Nivel de protección (en) arriba
≤2.8KV/4.5KV
Tipo de onda
Tipo II (T2)
Tipo de producto
SPD CC
Nivel de protección B,C,D Grado
D,C,B
Descripción

The Cooper Suntree three-module photovoltaic Surge Protective Device (SPD) (with three-step DC switching device) features visual indication and optional remote contact signaling (floating changeover contact) for use in PV systems. These complete surge protective devices are suitable for all PV systems in accordance with IEC 60364-7-712. Includes a five year limited warranty.

These pre-wired solutions consist of a base and locking modules that feature a combined disconnection and short-circuiting (shunting) device with safe electrical isolation to prevent fire damage due to DC arcs. An integrated DC fuse allows safe module replacement without arc formation. In case of insulation faults in the generator circuit, a reliable and tested fault-resistant `l circuit prevents damage to the surge protective devices.

The green and red visual indicator flags show the module protective status (green = good, red = replace). Apart from this visual indication,the remote signaling option features a three terminal floating changeover contact that can be used as a make or break contact depending on the particular monitoring system design employed.

¿Es nuevo en las compras en merXu?

Es más fácil de lo que piensa. Le proporcionamos una guía paso a paso

Negocie con el vendedor

Puede contactar al vendedor para ajustar su pedido, negociar el precio o preguntar acerca de otras ofertas de su portafolio antes de realizar una compra. Elija y haga clic en la oferta que le interesa. Encuentre el botón "ENVIAR CONSULTA" en el lado derecho de la oferta y se le dirigirá directamente a un chat con el vendedor