merXu

Cancel
merXu Protected Payments
Secure your payment until delivery.
Valve module (4 valves) - LEVEL 4

Valve module (4 valves) - LEVEL 4

Manufacturer Code
mH-S4-4
EAN
5908312593638
Width
0.105
Weight
0.21
Depth
0.104
Height
0.075
Show more
Request for quotes
This offer is not active anymore. Add an inquiry and get offers from multiple sellers.
Offer from supplier:
Login to see supplier details
Verified
Other sellers offer this product
€1.51
PLN 6.53
Cross connector 4-śrubowe M8 B=30mm (hot-dip galvanized steel) AN-04/OG/
EL-VID SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ
Verified
€8.43
PLN 36.59
€8.98
PLN 38.95
Kerakoll Color silicone 310 ml *24*
KIM Sp. z o.o.
Verified
€12.46
PLN 54.05
€33.55
PLN 145.53
Loge Morocco MA shower faucet 44 Gold
KIM Sp. z o.o.
Verified
€33.55
PLN 145.53
€39.17
PLN 169.92
Loge Morocco shower faucet MA 04
KIM Sp. z o.o.
Verified
€42.91
PLN 186.18
€62.24
PLN 270.00
€66.62
PLN 289.00
PV Module (Photovoltaic Panel) Leapton 400W fullblack LP182x182-M-54-MH 400 black frame
ECOWATT SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ
Verified
€68.00
PLN 295.00
PV Module (Photovoltaic Panel) Leapton 410W LP182x182-M-54-MH 410 black frame
ECOWATT SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ
Verified
€94.95
[container price] Leapton 410Wp LP182*182-M-54-MH (black frame 30mm)
BUY PV SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ
Verified
€96.84
[container price] Leapton 400Wp LP182*182-M-54-MH (black frame 30mm)
BUY PV SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ
Verified
Parameters
Manufacturer Code
mH-S4-4
EAN
5908312593638
Width
0.105
Weight
0.21
Depth
0.104
Height
0.075
Kod CN
9032102090
PKWiU
26.51.70.0
Description
The mH-S4 module is a four-channel controller that works with digital temperature sensors measuring temperatures in the range from +5 to +40 degrees with an accuracy of 0.1 degrees and is designed to work with mH-V4 executive modules that control solenoid valves in the heating circuit.The module is mounted in a switchgear and takes up a field of 5 modules, and the module supply voltage is 24 VDC.FTP cables from temperature sensors are brought to the module (one cable for each sensor).The module works autonomously on the basis of detailed settings entered from the touch panel (independently adjustable temperature and hysteresis for each room) and on the basis of these settings it directly controls the actuator that regulates the room temperature.If you need to connect more temperature sensors, you can use several mh-S4 modules, but remember that they must be modules of subsequent levels (mH-S4 - level 1, mH-S4-level 2, ...).Inputs / outputs The mH-S4 module is offered in various levels, thus enabling the expansion of the network of inputs / outputs connected to the F & amp; Home system.Install the module from level 1 first, then from level 2, etc.Each level has a separate numbering, which ensures easier installation of the installation.The list of outputs for the mH-S4 module is presented in the table below.Principle of operation FTP cables from temperature sensors (one cable for each sensor) are brought to the module.The module works autonomously on the basis of detailed settings entered from the touch panel (independently set temperature and hysteresis for each room) and on the basis of these settings it directly controls the executive module regulating the temperature in the room, while the principle is maintained that the operation is regulated based on the indications of the first module the first solenoid valve connected to the executive module.Programming the module takes place annually with a step of 15 minutes. which allows you to take into account the time of day, day of the week and seasonThe temperature can be read from the main touch panel.Remarks It is essential to observe the connection of the temperature sensors.Changing the order of the wires may result in damage to both the sensors and the mH-S4 module Each of the sensors is connected with three wires of the FTP cable, but it must be connected so that the sensor's signal wire (green) and the negative wire (white) are connected to one pair of FTP cable.Each sensor must be connected to a separate FTP cable

New to buying at merXu?

It’s easier than you think. We provide you with a step-by-step guide.

Negotiate with the seller

You can contact the seller to adjust your order, negotiate the price, or inquire about other offers from their portfolio before making a purchase. Choose and click on the offer you are interested in. Find the button "SEND INQUIRY" on the right side of the offer and you will be moved directly to a chat with the seller.

One Request, Multiple Quotes
Request for quotes by telling supplier what you need.