merXu
Cancel

LRM001 / 33-6 RS - Reactive Power Regulator - 3-phase current measurement, 6 stages RS

communication
RS485 Modbus / RTU
relative humidity
50% for + 40 ° C, 90% for 60 ° C
level of security
IP20
supply voltage
230 VAC ± 10%, 50 Hz
power consumption
up to a maximum of 10 VA
assembly
array
Show more
basic price
PLN 750.00
1 pc.
€158.88
5+ pcs.
PLN 712.50
1 pc.
€155.60
10+ pcs.
PLN 690.00
1 pc.
€150.69
15+ pcs.
PLN 682.50
1 pc.
€149.05
PLN 750.00 +VAT
€163.79
1 ×
PLN 750.00
(1 pc. )
  • Check before buy
  • Full flexibility
  • Free assistance
  • Condition new
  • Minimum order volume 1 pc.
  • Country of dispatch Poland
  • Destination countries Poland, Czechia, Slovakia, Estonia, Lithuania, Germany, Hungary, Romania
L
verified supplier
LOPI ANUSZKIEWICZ I TRZECIŃSCY SP.J.
Contact supplier
See all offers
see report
Parameters
communication
RS485 Modbus / RTU
relative humidity
50% for + 40 ° C, 90% for 60 ° C
level of security
IP20
supply voltage
230 VAC ± 10%, 50 Hz
power consumption
up to a maximum of 10 VA
assembly
array
dimensions
144x144x58 mm
weight
0.3 kg
working temperature
-25°C 60°C
Description

Friendly and functional software even for the most demanding users.

The Lopi microprocessor reactive power factor regulators are the result of the work and experience of Lopi engineers and a response to the current market needs.The controller with effective algorithms ensures optimal operation of the reactive power compensation system, and thus effective minimization of costs incurred for reactive energy .Reactive power regulators are used to control capacitor banks and shunt reactor batteries as part of reactive power compensation processes.This process consists in measuring the network parameters and then, by using thyristor switches or contactors, switching on the appropriate component of the compensation system in order to ensure the desired cosφ. Lopi reactive power regulators have a wide range of applications, as they are designed to work in automatic reactive power compensation systems, both inductive and capacitive .The device is available in 6- and 12-step versions with network parameter measurement in one or three phases.This enables optimal adjustment - depending on the number of stages, the design power of the battery and the symmetry of the load.

Application

  • inductive reactive power compensation: works with capacitive stages
  • capacitive reactive power compensation - works with inductive stages
  • reactive power compensation in case of its variable capacitive-inductive character
  • compensation in networks with symmetrical and asymmetric loads - single or three-phase measurement and control of single and / or three-phase elements
  • Functions

  • display of cosφ and Power Factor
  • idle compensation function
  • reactive power offset function
  • uniform algorithm stage consumption
  • the possibility of any programming of the type and power of individual outputs (no series imposed)
  • quick algorithms for reaching the set cosφ factor
  • individually set discharge times (locks) degrees
  • the ability to control the housing ventilation based on op temperature measurement and set hysteresis
  • steps disconnection in case of exceeding set threshold temperature
  • possibility of remote reading
  • 3-phase current measurement, 6 degrees