merXu
Cancel

Frequency converter =< 1 kV Siemens 6SL32101KE143AF2 50/60 Hz 3 3 U converter IP20

Manufacturer
Siemens
Manufacturer Code
6SL32101KE143AF2
EAN
4042948668825
Mains frequency
50/60 Hz
Number of phases input
3
Number of phases output
3
Show more
PLN 2,899.10
PLN 1,826.44
€396.56
1 pc.
*Special offer
PLN 1,826.44+VAT
€396.56
1 ×
PLN 1,826.44
(1 pc.)
  • Check before buy
  • Full flexibility
  • Free assistance
  • Condition new
  • Minimum order volume 1 pc.
  • Country of dispatch Poland
  • Destination countries Czechia, Estonia, Lithuania, Poland, Slovakia
  • Delivery price
    PLN 20.00
E
verified supplier
Elmark Sp. J. Jędrzejewska
Contact supplier
See all offers
see report
Parameters
Manufacturer
Siemens
Manufacturer Code
6SL32101KE143AF2
EAN
4042948668825
Mains frequency
50/60 Hz
Number of phases input
3
Number of phases output
3
Type of converter
U converter
Degree of protection (IP)
IP20
Max. output frequency [Hz]
550
Max. output voltage [V]
480
Nominal output current I2N [A]
4.3
Max. output at quadratic load at rated output voltage [kW]
1.5
Max. output at linear load at rated output voltage [kW]
1.1
Relative symmetric net frequency tolerance [%]
5
Relative symmetric net voltage tolerance [%]
-20
Number of analogue outputs
1
Number of analogue inputs
1
Number of digital outputs
2
Number of digital inputs
6
Number of HW-interfaces industrial Ethernet
2
Number of interfaces PROFINET
2
Number of HW-interfaces RS-232
1
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
1
Number of HW-interfaces USB
1
Number of HW-interfaces parallel
0
Number of HW-interfaces other
6
Height [mm]
173
Width [mm]
73
Depth [mm]
160
Application in industrial area permitted
Yes
Application in domestic- and commercial area permitted
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
Yes
Supporting protocol for SafetyBUS p
No
Supporting protocol for BACnet
No
Supporting protocol for other bus systems
Yes
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
Yes
4-quadrant operation possible
No
Mains voltage [V]
380 - 480