merXu
Annuller
merXu Protected Payments
Sikre din betaling indtil levering.
ADELID overspændingsafleder 3faz B+C 4P OPX
ADELID overspændingsafleder 3faz B+C 4P OPX
ADELID overspændingsafleder 3faz B+C 4P OPX

ADELID overspændingsafleder 3faz B+C 4P OPX

Producent
ADELID
Tilmeld eller Log på for at starte med at handle
Tilbud fra leverandøren:
Log ind for at begynde at shoppe
Verificeret
Afsendelsesland:
Polen
Bestemmelseslande:
+26 mere
Tilgængelighed:
Afsendelsestidspunkt:
2 dage
Betalingsmetoder anbefalet af merXu:
Anbefalet af merXu
merXu Protected Payments
merXu Protected Payments
Sikre din betaling indtil levering. Gratis.
Få mere at vide
Alternative betalingsmetoder:
Blik
Kredit-/debetkort
Netbank
Bankoverførsel
Parametre
Producent
ADELID
Beskrivelse

SURGE LIMITER CLASS (T1+T2) B+C 4P 6kA

ADELID OPX % p11/%

(THREE-PHASE)

TECHNICAL DATA:

Model - OPX-B+C

Protection class - T1+T2 (B+C)

Compliance with requirements - class I+II

Version - varistor

Poles - %p43/ %

Protection required - 32A

Connections max - 35mm2 %p54/ %

Maximum operating voltage - Uc 385 V AC

Test current (8/20) In - %p64 /%

Max. current (8/20) Imax - 60kA

Voltage protection level - 1,5 kV

%p78/ % Assembly - rail 35mm

Storage temperature - -30/+70°C

Operating ambient temperature - -30/+50°C

Tightness class - IP 20

Surge arresters class B+C: %p99 /%

- They are dedicated to protecting LV power supply installations against the effects of induced and switching overvoltages.They can be installed in networks such as: TN, TNC, TNCS, TNS, TT.

- They should be used as both the first and second level of protection in floor boards and sub-distributions.The arresters should be installed at the points where the electrical installation enters the building.

- They provide complete protection of the electrical installation and the electrical devices supplied from it against the effects of part of the lightning current and other types of overvoltages.

- They reduce overvoltages and bring surge currents from both types of overvoltages - direct and indirect - to the ground.They also provide a two-stage level of protection.

- Provide effective protection for computers, electronics/home appliances, etc.

- They are equipped with a visual operation indicator (green - protection, red - no protection).

SURGE PROTECTORS ARE EQUIPPED WITH A VISUAL OPERATION INDICATOR:

  • green – protection

    %p9 /%
  • red –  no protection

Ny til at købe hos merXu?

Det er lettere, end du tror. Vi giver dig en trin-for-trin vejledning

Forhandle med sælgeren.

Du kan kontakte sælgeren for at justere din ordre, forhandle om prisen eller forespørge om andre tilbud fra deres portefølje, inden du foretager et køb. Vælg og klik på det tilbud, du er interesseret i. Find knappen "SEND FORESPØRGSEL" på højre side af tilbuddet, og du vil blive ført direkte til en chat med sælgeren

Én anmodning, flere tilbud
Skab en forespørgsel ved at fortælle leverandøren, hvad du har brug for.